ugc approved journal list IJRTI Research Journal
International Journal for Research Trends and Innovation
An International Open Access Journal
Impact Factor: 4.87

Call For Paper

Issue: December 2018

Volume 3 | Issue 12

Impact Factor: 4.87

Submit Paper Online

Click Here For more Details

For Authors

Forms / Download

Editorial Board

Subscribe IJRTI

Facts & Figure

Impact Factor : 4.87

Issue per Year : 12

Volume Published : 3

Issue Published : 31

Article Submitted : 1286

Article Published : 778

Total Authors : 2080

Total Reviewer : 503

Total Pages : 60

Total Countries : 12

Visitor Counter


Indexing Partner

Published Paper Details
Paper Title: Experimental Study and performance analysis of transformer cooling system
Authors Name: Aradhana Saket , Mrs. Seema Pal , Dr. A.K. Sharma
Unique Id: IJRTI1809016
Published In: Volume 3 Issue 9, September-2018
Abstract: Transformer plays an important role in electrical power system .There are many problems associated with Power loss in transformer but in this paper mainly focuses on efficient cooling system designed for overcoming heating and insulation losses. Ever since the invention of a transformer, we have been facing the trend of increasing its nominal power. Together with the increase of nominal power, losses in transformers increase as well, while a transformer's own capability of cooling decreases. The efficiency of the cooling is a crucial factor determining the operational safety and the life span of a transformer. Based on previous research works, this paper compares four cooling methods (air natural, air forced, air forced water forced and air forced water forced with coolant cooling) with the help of experimental setup. In this experimental setup comprises copper tube, air fan, water circulating pump. And the result better found in the air forced water forced with coolant cooling method .By using this method, the temperature of transformer can be reduced in short time. According to generally adopted estimate states that if a transformer’s maximum operating temperature is reduced by 6°C-10°C the thermal life of insulation system is approximately doubled. The main purpose of the experiment is to improve the cooling system of transformer, to increase the life expectancy of transformer.
Keywords: Transformer, IR Controller, Copper tube, Coolant.
Cite Article: "Experimental Study and performance analysis of transformer cooling system", International Journal of Science & Engineering Development Research (www.ijrti.org), ISSN:2455-2631, Vol.3, Issue 9, page no.91 - 98, September-2018, Available :http://www.ijrti.org/papers/IJRTI1809016.pdf
Downloads: 000674
Publication Details: Published Paper ID: IJRTI1809016
Registration ID:180462
Published In: Volume 3 Issue 9, September-2018
DOI (Digital Object Identifier):
ISSN Number: 2456 - 3315
Share Article:

Click Here to Download This Article

Article Preview



Major Indexing from www.ijrti.org
Google Scholar ResearcherID Thomson Reuters Mendeley : reference manager Academia.edu
arXiv.org : cornell university library Research Gate CiteSeerX DOAJ : Directory of Open Access Journals
DRJI Index Copernicus International Scribd DocStoc

ISSN Details

DOI (A digital object identifier)



Providing A digital object identifier by DOI
How to GET DOI and Hard Copy Related

RMS

Conference Proposal

Latest News / Updates

Open Access License Policy

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License

Creative Commons License This material is Open Knowledge This material is Open Data This material is Open Content

Important Details

Social Media

Untitled Document